DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)

Аперацыя ад цеплавой перагрузкі серыі DAM1-125 Аўтаматычны выключальнік у літым корпусе (фіксаванага тыпу)

Аўтаматычныя выключальнікі серыі DAM1 прызначаны для правядзення току ў нармальным рэжыме і яго адключэння пры кароткіх замыканнях, перагрузках, недапушчальных перакрыццях, а таксама аператыўнага спрацоўвання і адключэння частак электрычных ланцугоў. Яны прызначаны для выкарыстання ў электрычных агрэгатах з абмежаваным працоўным напружаннем 400 В на намінальны ток ад 12,5 да 1600 А. Яны адпавядаюць патрабаванням EN 60947-1, EN 60947-2

  • Апісанне прадукту
  • Тэхнічныя характарыстыкі
  • Асаблівасці прадукту
  • Больш падрабязна

Апісанне прадукту

    Аўтаматычныя выключальнікі серыі DAM1 прызначаны для правядзення току ў нармальным рэжыме і яго адключэння пры кароткіх замыканнях, перагрузках, недапушчальных перакрыццях, а таксама аператыўнага спрацоўвання і адключэння частак электрычных ланцугоў. Яны прызначаны для выкарыстання ў электрычных агрэгатах з абмежаваннем працоўнага напружання 400В на намінальны ток ад 12,5 да 1600А. Яны адпавядаюць патрабаванням EN 60947-1, EN 60947-2 


Цеплавыя магнітныя выключальнікі:

    Функцыя цеплавой абароны: (Для абароны ва ўмовах перагрузкі) Біметал,  які забяспечвае цеплавую абарону, складаецца з камбінацыі двух металаў з рознымі каэфіцыентамі пашырэння пры награванні. Калі біметал награваецца, ён згінаецца да металу з меншым выцягваннем. Такім чынам, выемка, якая дапамагае адкрыць механізм выключальніка, вызваляецца, каб адключыць выключальнік. Хуткасць выгібу біметалу прама прапарцыйная велічыні току, які праходзіць праз выключальнік. Таму што павелічэнне току азначае павелічэнне цяпла. Такім чынам, функцыю абароны ад перагрузкі па току выключальніка выконвае біметал пры токах нагрузкі, большых за намінальны.


Функцыя магнітнай абароны (Для абароны ад кароткага замыкання)

    Яшчэ адной функцыяй выключальніка з'яўляецца абарона падключанага ланцуга ад кароткага замыкання. Кароткае замыканне можа адбыцца ў выніку кантакту фаз паміж сабой або кантакту фаза-зямля. Паколькі ў выпадку кароткага замыкання па кабелях праходзіць вельмі вялікі ток, дзякуючы цеплавой абароне энергія сістэмы павінна быць адключана за больш кароткі час. Выключальнік павінен імгненна адчыняцца, каб абараніць нагрузку, да якой ён падключаны. Дэталь, якая выконвае гэтую функцыю, - гэта механічны механізм адчынення, які працуе з намагнічанасцю, выкліканай намагнічанасцю, утворанай токам кароткага замыкання.

    Аўтаматычныя выключальнікі ў літым корпусе - гэта нізкавольтныя выключальнікі. Яны задавальняюць патрэбы ў ўстаноўцы ад дробных карыстальнікаў да вялікіх прамысловых падстанцый і сістэм размеркавання электраэнергіі. Яны звычайна прымяняюцца на сталеліцейных заводах, нафтавых платформах, бальніцах, чыгуначных сістэмах, аэрапортах, вылічальных цэнтрах, офісных будынках, канферэнц-цэнтрах, тэатрах, хмарачосах і іншых буйных збудаваннях.


Тэхнічныя характарыстыкі

Электрычныя параметры аўтаматычнага выключальніка ў літым корпусе DAM1 MCCB


Цепламагнітны фіксаваны MCCB

Фота

мадэль

код

  Іку (Канада)

ІС (KA)

Намінальны ток

Ui(V)

Ue(V)

паляк

Uimp(V)

DAM1-160 1P MCCB moulded case circuit breaker.jpg

ДАМ1-160

Б

25

18.75

10 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63- 80 - 100 - 125-160А

500В

230В

10000

Н

36

27

DAM1-250 3P moulded case circuit breaker.jpg

ДАМ1-200

Б

25

18.75

10 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63- 80 - 100 - 125-160(200)А

750В

400В

10000

Н

36

27

DAM1-125 3P

DAM1-125 4P


ДАМ1-125

Б

25

12.5

10 - 12,5 - 16 - 20 - 25 - 32(30) - 40 - 50 - 63(60) - 80 - 100 - 125А

750В

400В

3P / 4P

10000

Н

35

17.5

С

50

37.5

DAM1-160 2P MCCB moulded case circuit breaker

DAM1-160 3P moulded case circuit breaker


ДАМ1-160

Б

25

12.5

10- 12,5-16-20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 -125 - 160(150)А

750В

400/415В

3P / 4P

8000

Н

35

26.25

С

50

37.5

DAM1-250 3P moulded case circuit breaker

ДАМ1-250

Н

35

26.25

63 - 80-100-125 - 160(180) - 200(225) - 250(320)А

750В

400/415В

3P / 4P

8000

С

50

37.5

Х

65

48.75

Г

85

51

DAM1-400 4P MCCB moulded case circuit breaker

DAM1-630(400)

Н

35

26.25

250 - 315 (350) - 400 - 500 - 630 А

750В

400/415В

3P / 4P

8000

С

50

37.5

Х

70

52.5

Г

85

52.5

DAM1-800 MCCB moulded case circuit breaker

ДАМ1-800

Н

35

35

400 - 500 - 630 (700) - 800 -1000 А

750В

400/415В

3P / 4P

8000

С

50

37.5

Х

70

52.5

Г

85

52.5

微信图片_20241112163716

ДАМ1-1600

С

65

50

800 -1000 - 1250 - 1600А

750В

400В

3P / 4P

8000

Х

85

50

Г

100

50


·Іку:O-t-CO тэст (O:Адкрыты манеўр,CO:Зачынены-Адкрыты манеўр,t:Працягласць чакання)

·ICS:O-t-CO-t-CO тэст (O:адкрыты манеўр,CO:зачынены-адкрыты манеўр,t:працягласць чакання)

ON/I Пазіцыя:Паказвае, што кантакты выключальніка замкнёныя. У гэтым становішчы рычаг выключальніка знаходзіцца ў верхнім становішчы

TRIP Пазіцыя:Паказвае, што выключальнік размыкнуты з-за якой-небудзь няспраўнасці (перагрузкі або кароткага замыкання). У гэтым выпадку рычаг выключальніка знаходзіцца ў сярэднім становішчы паміж становішчам ON і OFF. Каб перавесці выключальнік, які знаходзіцца ў становішчы адключэння, у становішча ON; націсніце рычаг выключальніка ўніз, як паказана знакам OFF

Выключальнік павінен быць усталяваны са пстрычкай. Пасля гэтага пацягніце рычаг, як паказана знакам ON, каб зачыніць выключальнік

Становішча OFF/0:Паказвае, што кантакты выключальніка размыкаюцца. Такім чынам, рычаг выключальніка знаходзіцца ў ніжнім становішчы.

 

Фізічныя параметры аўтаматычнага выключальніка ў літым корпусе DAM1 MCCB

Катэгорыя (EN 60947-2/IEC 60947-2)

Цягавітасць



мадэль

паляк

Дыэлектрычныя ўласцівасці (V)

адлегласць ланізацыі (мм)

Усяго цыклаў

Электрычнае жыццё

Механічнае жыццё

Галоўны контур

Дапаможны контур

ДАМ1-160

2500

≤30/0

20000

3000

17000

А/0

АС-15

ДАМ1-200

2500

≤30/0

15000

2500

12500

А/0

АС-15

ДАМ1-125

3P / 4P

2500

≤30/0

8000

1000

7000

А/0

АС-15

ДАМ1-160

3P / 4P

3000

≤30/0

8000

1000

7000

А/0

АС-15

ДАМ1-250

3P / 4P

3000

≤30/0※

8000

1000

7000

А/Б

АС-15

DAM1-630(400)

3P / 4P

3000

≤60/0※

5000

1000

4000

А/Б

АС-15

ДАМ1-800

3P / 4P

3000

≤80/0※

5000

1000

4000

А/Б

АС-15

ДАМ1-1600

3P / 4P

3000

≤80/0※

3000

500

2500

А/Б

АС-15

 

>> Памер аўтаматычнага выключальніка ў літым корпусе MCCB

мадэль

паляк

 

Абрысны памер

(ДХШХВ)

 

ДАМ1-160

120х30х70 мм

ДАМ1-200

120х60х70 мм

ДАМ1-125

120x76x70 мм

120x101x70 мм

ДАМ1-160

120x90x70 мм

120х120х70 мм

ДАМ1-250

170x105x103,5 мм

170x140x103,5 мм

DAM1-630(400)

254x140x103,5 мм

254x184x103,5 мм

ДАМ1-800

268x210x103,5 мм

268x280x103,5 мм

ДАМ1-1600

410x210x138,5 мм

410x280x138,5 мм


Асаблівасці прадукту

Лёгкая самастойная ўстаноўка дапаможных прылад:

  Трывожны кантакт;

  Дапаможны кантакт;

  Расцепитель пад напругай;

  Шунтавы расцепитель;

  Ручка прывада;

  Электрычны механізм прывада;

  Устаўное прылада;

  Выкатная прылада;.

  Стандартны камплект кожнага аўтаматычнага выключальніка складаецца з злучальных шын або кабельных наканечнікаў, фазоразделителей, набору шруб і гаек для яго мацавання на мантажнай панэлі.

  З дапамогай спецыяльнага заціску блокі 125 і 160 можна ўсталяваць на DIN-рэйку.

  Вага і габарыты гэтых аўтаматычных выключальнікаў на 10-20% менш, чым прапанаваныя іншымі айчыннымі вытворцамі. Гэты факт прадугледжвае мантаж скрынак і панэляў меншага памеру. Акрамя таго, невялікія габарыты дазваляюць памяняць старыя выключальнікі на DAM1.

Відэа

Там, дзе вам патрэбна эфектыўнае рашэнне, вам патрэбны запыт

Вам патрэбна прафесійная каманда, каб даць вам рашэнні? Звяжыцеся з намі, каб атрымаць прапанову

×

Звяжыцеся з намі

* Мы паважаем вашу прыватнасць. Калі вы адпраўляеце сваю кантактную інфармацыю, мы згаджаемся звязвацца з вамі толькі ў адпаведнасці з нашыміПалітыка прыватнасці.

×

Запытайцеся

*Імя
*Электронная пошта
*Назва кампаніі
*тэл
*паведамленне

* Мы паважаем вашу прыватнасць. Калі вы адпраўляеце сваю кантактную інфармацыю, мы згаджаемся звязвацца з вамі толькі ў адпаведнасці з нашыміПалітыка прыватнасці.