DAM2 Kompakt Tip Devre Kesici

DAM2 serisi devre kesicinin nominal yalıtım voltajı 800V'dir, AC 50Hz / 60Hz dağıtım ağı, 690V nominal çalışma voltajı ve 1250A nominal akım için uygundur, gücü dağıtmak ve devreyi ve güç ekipmanını hasardan korumak için aşırı yük, kısa devre, düşük voltaj ve diğer arızalarla. 

  • Ürün Açıklaması
  • Özellikler
  • Ürün Özellikleri
  • Daha Fazla Detay

Ürün Açıklaması

  DAM2 serisi devre kesicinin nominal yalıtım voltajı 800V'dir, AC 50Hz / 60Hz dağıtım ağı, 690V nominal çalışma voltajı ve 1250A nominal akım için uygundur, gücü dağıtmak ve devreyi ve güç ekipmanını hasardan korumak için aşırı yük, kısa devre, düşük voltaj ve diğer arızalarla. Ayrıca devrelerin seyrek dönüşümü ve motorun seyrek başlatılması ve aşırı yük, kısa devre koruması için devre, voltaj altında.    DAM2(CM1) devre kesici dikey (dik) veya yatay (enine) olarak monte edilebilir.

 

  Ortam hava sıcaklığı: -5°C~+40°C ve 24 saatlik ortalama sıcaklık +35°C'nin altındadır.
 

  Rakım: Kurulum yerinin rakımı 2000 m'den fazla değildir.
 

  Atmosfer koşulları: En yüksek sıcaklık +40°C'de havanın bağıl nemi %50'den fazla değildir;


  Düşük sıcaklıklarda bağıl nem daha yüksek olabilir. Maksimum ortalama bağıl nem %90, ortalama aylık minimum sıcaklık ise +25°C'dir ve jelin yüzeyindeki üründeki sıcaklık değişikliklerini dikkate alın.


Özellikler

Direğe göre dört türü sınıflandırır.:
    A tipi: Aşırı akım serbest bırakma bileşenleri olmayan N-kutbu ve N-kutbu baştan sona bağlanmıştır ve diğer üç kutupla birlikte açılıp kapatılmaz;

    B tipi: Aşırı akım serbest bırakma bileşenleri olmayan N-kutbu ve N-kutbu diğer üç kutupla birlikte hareket edebilir (kapanmadan önce N-kutbunun açılması);
    Tip C: Aşırı akım serbest bırakma bileşenleri ile sabitlenmiş N-kutbu ve N-kutbu diğer üç kutupla birlikte hareket edebilir (kapanmadan önce N-kutbunun açılması);

Aşırı akım bobininin nominal akımına göre sınıflandırma:
DAM2(CM1)-63 MCCB'de dokuz adet bulunur: 6,10,16,20,25,32,40,50,63 A;
DAM2(CM1)-100 MCCB'de dokuz adet bulunur: 16,20,25,32,40,50,63,80,100 A;
DAM2(CM1)-250 MCCB'nin yedisi vardır: 100,125,140,160,180,200,225 ,250A;
DAM2(CM1)-400 MCCB'de beş adet bulunur: 225,250,315,350,400 A;
DAM2(CM1)-630 MCCB'de üç tane bulunur: 400.500.630 A;
DAM2(CM1)-800 MCCB'de üç adet bulunur: 630,700,800A;
DAM2(CM1)-1250 MCCB'de üç adet bulunur: 800,1000,1250A.
    Açıklama: 6A yalnızca elektromanyetik (anlık) tiptedir, tavsiye edilen özellikler değildir.
    Kablolama yöntemine göre: kablolama kartın önünde, kablolama kartın arkasında, kartın yerleştirme tipi.
    Aşırı akım salınım düzenine göre: termodinamik-elektromanyetik (çift) tip, elektromanyetik (anlık) tip.
    Kıyafetine göre kıyafetli ve kıyafetsiz olmak üzere iki çeşidi vardır.
    Kıyafet, iç aksesuarları ve dış aksesuarları içerir: İç aksesuarlarda şönt bobini, düşük voltaj bobini, yardımcı kontak ve alarm kontağı bulunur. Dış aksesuarlar, döner kol çalıştırma mekanizması, güçle çalışan çalıştırma mekanizması vb.'dir.
     Kırma kapasitesine göre: L-standart kırma tipi; M-saniye yüksek kırılma tipi; H-yüksek kırılma tipi


Teknik parametreler

 

    1, Dağıtım için devre kesicinin anlık hareket karakteristiği ayar değeri 10In±%20, DAM2(CM1)-1250 7In±%20'dir; Motor koruması için devre kesicinin anlık hareket karakteristiği ayar değeri 12In ± %20'dir.


    2, Tablo 2.3'teki devre kesicinin nominal değeri, +40°C ortam sıcaklığında, Tablo 3'te gösterilen dağıtım aşırı akım serbest bırakma eylemi özellikleri için devre kesici, motor koruma aşırı akım serbest bırakma eylemi özellikleri için devre kesici Tablo 4'te gösterilmiştir.


Modeli

Kutup

Nominal akım (A)

derecelendirildi
işletme
voltaj (V)

derecelendirildi
yalıtım
voltaj (V)

Nominal nihai kısa devre kesme kapasitesi (Icu)

Flashover
mesafe(mm)

Test voltajı (V)

Akım (kA)

IC'ler (kA)

BARAJ2(CM1)L-63

3

10、1620、25、32、40、50、63

400

500

400×1.10

25

18

0

BARAJ2(CM1)M-63

3、4

50

35

BARAJ2(CM1)L-100

3、4

16、2025、32、40、50、63、80、100

400

800

30

22

≤50

BARAJ2(CM1)M-100

2、3、4

50

35

BARAJ2(CM1)H-100

3

85

50

BARAJ2(CM1)L-100

3、4

690

10

5

BARAJ2(CM1)M-100

2、3、4

20

10

BARAJ2(CM1)L-225

3、4

100、125、140、160、180、200、225

400

800

35

25

BARAJ2(CM1)M-225

2、3、4

50

35

BARAJ2(CM1)H-225

3

85

50

BARAJ2(CM1)L-225

3、4

690

10

5

BARAJ2(CM1)M-225

2、3、4

20

10

BARAJ2(CM1)L-400

3

225、250、315、350、400

400

800

50

35

≤100

BARAJ2(CM1)M-400

3、4

65

42

BARAJ2(CM1)H-400

3

100

65

BARAJ2(CM1)L-400

3

690

15

8

BARAJ2(CM1)M-400

3、4

20

10

BARAJ2(CM1)L-630

3

400、500、630

400

800

50

35

BARAJ2(CM1)M-630

3、4

65

42

BARAJ2(CM1)H-630

3

100

65

BARAJ2(CM1)L-630

3

6910

15

8

BARAJ2(CM1)M-630

3、4

20

10

BARAJ2(CM1)M-800

3

630、700、800

400

800

75

50

BARAJ2(CM1)H-800

3

100

65

BARAJ2(CM1)M-800

3

4690

30

15

BARAJ2(CM1)-1250

3

800、1000、1250

400

800

85

42

BARAJ2(CM1)-1250

3

690

25

12.5


Devre kesmenin nominal değeri

 

     Not: 2 kutuplu, 4 kutuplu devre kesiciler L, M, H olarak bölünmüş olup, M tipi ile aynı kırılma indeksine sahiptirler.

    Her kutup aynı anda açıldığında güç dağıtımı için devre kesicilerin aşırı akım salınımının ters zaman kesme eyleminin özellikleri


HAYIR.

Test akımı

G/GİRİŞ

Zamanı ayarla

Başlangıç ​​durumu

1

Geleneksel açmasız akım

1.05

2h(In>63A), 1h(In≤63A)

Soğuk

2

Geleneksel açmasız akım

1.30

2h(In>63A), 1h(In≤63A)

Test 1'den hemen sonra

    

     Dağıtım için devre kesicinin anlık hareket karakteristiği ayar değeri 10In±%20, motor koruma için devre kesicinin anlık hareket karakteristiği ayar değeri 12In±%20'dir.

     Her kutup aynı anda açıldığında motor koruması için devre kesicilerin aşırı akım bırakma işleminin ters zaman kesme eyleminin özellikleri


HAYIR.

G/GİRİŞ

Zamanı ayarla

Başlangıç ​​durumu

Açıklama

1

1.0

>2 saat

Soğuk


2

1.2

≤2h

Test 1'den hemen sonra


3

1.5

≤4 dakika

Soğuk

10≤n≤225

≤8 dakika

225

4

7.2

4S≤t≤10s

Soğuk

10≤in≤225

6S≤t≤20s

225

Aksesuarlar ters zaman koruma karakteristik eğrisi


图片1.jpg

图片2

图片3

图片4

图片5

图片6

Çeşitli Faktörler Sıcaklık Değişiklikleri Tablosu


Model/katsayı/sıcaklık                       

+40℃     

+45℃    

+50℃   

+55℃   

+60℃  

DAM2 (CM1) -63

1

0.94

0.88

0.80

0.72

DAM2 (CM1) -100

1

0.95

0.89

0.84

0.76

DAM2 (CM1) -225

1

0.96

0.91

0.87

0.82

DAM2 (CM1) -400

1

0.94

0.84

0.80

0.73

DAM2 (CM1) -630

1

0.93

0.88

0.83

0.76

DAM2 (CM1) -800

1

0.93

0.88

0.83

0.76

BARAJ2(CM1)-1250

1

0.88

0.83

0.79

0.76


Anahat ve kurulum boyutları

Tahtanın önündeki kabloların boyutu


图片7


Model                                          

H                             

H1                       

H2                                   

DAM2 (CM1) -63L/3p

74

89

19

DAM2 (CM1) -63m/3p

82

98.5

28.5

DAM2 (CM1) -63H/3P

82

98.5

28.5

DAM2 (CM1) -63L/4p

-

-

-

DAM2 (CM1) -63m/4p

-

-

-

DAM2 (CM1) -63H/4P

-

-

-



Model                                                               

H                           

H1                  

H2                      

DAM2 (CM1) -100L/2P

86

104

24

DAM2 (CM1) -100L/3P

68

86

24

DAM2 (CM1) -100m/3p

86

104

24

DAM2 (CM1) -100H/3P

86

104

24

DAM2 (CM1) -100m/4p

86

104

24

DAM2 (CM1) -100H/4P

86

104

24



Model                                                           

H                              

H1                    

H2                     

DAM2 (CM1) -225L/2p

104

127

24

DAM2 (CM1) -225L/3P

86

110

24

DAM2 (CM1) -225m/3p

103

127

24

DAM2 (CM1) -225H/3P

103

127

24

DAM2 (CM1) -225m/4p

103

127

24

DAM2 (CM1) -225H/4P

103

127

24



Model                                                               

H                      

H1                     

H2                       

DAM2 (CM1) -400L/3P

-

-

-

DAM2 (CM1) -400m/3p

-

-

-

DAM2 (CM1) -400H/3P

-

-

-

DAM2 (CM1) -400L/4P

-

-

-

DAM2 (CM1) -400m/4p

-

-

-

DAM2 (CM1) -400H/4P

-

-

-



Model                                                                 

H                           

H1                   

H2                   

DAM2 (CM1) -630m/3p

-

-

-

DAM2 (CM1) -630H/3P

-

-

-

DAM2 (CM1) -630m/4p

-

-

-

DAM2 (CM1) -630H/4P

-

-

-



Model                                               

H                                   

H1                          

H2                      

DAM2 (CM1) -800H/3P

-

-

-

DAM2 (CM1) -800H/4P

-

-

-


1 、 Devre kesicilerin iç aksesuarı

  

    1.1 Şant Sürümü
Şant salınımının nominal kontrol besleme voltajı: AC50Hz, 230V, 400; DC110V, 220V, 24V; %70 ~%110 arasında, devre kesiciyi güvenilir bir şekilde kırabilir.

    Şant salınımının dc24V olarak derecelendirilmiş kontrol besleme voltajı olduğunda, bakır telin maksimum uzunluğu aşağıdaki gereksinimleri karşılamalıdır.


Nominal Kontrol
Besleme Voltajı UC (DC24V)/İletken Alanı

1.5mm²

2.5mm²

%100 UC
%85 UC

150m
100m

250m
160m


    Yukarıdaki tablonun gereksinimleri yerine getirilmezse, aşağıdaki şekle kullanarak şant salınım kontrol devresinin tasarlanması önerilir

    Yukarıdaki tablonun gereksinimleri yerine getirilmezse, aşağıdaki şekle kullanarak şant salınım kontrol devresinin tasarlanması önerilir


图片26

1.2 Voltajlı Sürüm

  

    Güç kaynağı voltajı, aralığın% 70 ila% 35'inin voltajlı salım nominal voltajına düştüğünde, voltajlı salım devre kesici güvenilir kırılma; Besleme voltajı nominal voltaj düşük voltaj salımının%35'inin altında olduğunda, devre kesicinin kapalı olmasını önlemek için voltaj bırakma; Besleme voltajı, voltaj salımının nominal voltajının% 85'inden yüksek olduğunda, voltajlı salınım devre kesicinin kapatılmasını sağlar. Düşük voltaj salınımları AC50Hz, 230V, 400V olarak derecelendirilmiştir.
    Özel Not: Yetersiz gerilim salımına sahip devre kesici, sadece açılıp kapatılabilen nominal voltajlı düşük voltajda
normalde.


1.3 Ön ödemeli metre özel sürüm

   

Sınıflandırma

Geleneksel termal akım (Ith)

400V IE (AC-15)

Değerlendirilmiş Akım Whendc 220V IE (DC-13)

Yardımcı kontak

3

0.4

0.15

Alarm kontağı

3

0.3

0.15


1.4 Yardımcı Kontaklar ve Alarm Kişileri 

A. Yardımcı temas


B. Alarm kontağı
   Alarm kontakları, devre kesici normal açıldığında ve kapandığında hareket etmez, alarm kontakları normal açıklık ve normal kapanış arasında geçiş yapmaz, ancak serbest açma veya arıza açıldıktan sonra.


2 、 Devre kesiciler için harici aksesuar

 2.1 Motor Çalışma Mekanizması. Nominal değer ve kod Tablo 6'da gösterilmiştir.


Kategori/Model

DAM2 (CM1) -63. 125. 250

DAM2 (CM1) -400. 630. 800. 1250

Yapı tipi

Elektromıknatıs

Motor

AC voltaj kodu

AC50Hz 、 230V 、 400

AC50Hz 、 230V 、 400

DC Voltaj Kodu

DC110V 、 220V

DC110V 、 220V

 

    NOT: Devre kırıcının elektrikli çalışma mekanizması ile açılmasından sonra, elektrik çalışma mekanizması devre kırıcı tokasını tekrar yapmalıdır, sonra kapanabilir.

    DAM2 (CM1) -63、100、225 Elektrik Çalışma Mekanizması (AC) açılışının ve kapanışının temel diyagramı

图片31

    DAM2 (CM1) -400、630、800、1250 Elektrik Çalışma Mekanizması (AC) açılışının ve kapanışının temel diyagramı


图片32


2.2 Tablo 10'da gösterilen manuel çalışma mekanizmasının kurulum boyutları
DAM2 (CM1) -63 ~ 800'ün sap montaj deliğinin diyagramı


图片33


Devre Kesicinin Toplam Yüksekliği/Manuel Çalışma Mekanizması (MM) (Tablo 12'de gösterilmiştir)


Modeli

Toplam elektrik yüksekliği
çalışma mekanizması h

Manuel çalışma mekanizmasının kurulum boyutları h

BARAJ2(CM1)L-63

155

49

DAM2 (CM1) M/H-63

164

49

BARAJ2(CM1)L-100

152

51

DAM2 (CM1) M/H-100

170

51

BARAJ2(CM1)L-225

182

54

DAM2 (CM1) M/H-225

199

54

DAM2 (CM1) L/M/H-400

255

88

DAM2 (CM1) M/H-630

262

89

DAM2 (CM1) M/H-800

261

96

DAM2 (CM1) H-1250

290

103


 DAM2 (CM1) Serisi Kalıplı Kılıf Devre Kesici Hızlı Seçim Tablosu Nasıl Yapılır

 DAM2 (CM1) -225 L P/3 3 10 2 T 200a

 

Karşılıklı
edebiyat

İşlev adı

Modele karşılık gelen işlev

A

Model Özellikleri

DAM2 (CM1) Kalıplı Casecircuit Breaker

B

Çerçeve derecelendirilmiş akım kodu

63a 、 100a 、 225a 、 400a 、 630A 、 800A 、

1250A

C

Kapasite Kırma özelliği
kod

L-standart kırılma tipi; m-saniyelik yüksek kırılma tipi;

H-yüksek kırma tipi

D

Çalışma Modu Kodu

Saplı çalışma için kod yok; elektrikli çalışma için P;

T Halkı İşlemini Dönüş İçin Z

e

Kutup

2-iki kutuplar; 3-üç kutup;

4 dört kutup

F

Serbest Bırakma Adı

2 Elektromanyetik Serbest Bırakma; 3 Çift Serbest Bırakma

G

Aksesuar

00 aksesuarsız
08 Alarm Kişisi
10 şant sürümü
20 Yardımcı İletişim
30 Düşük voltaj sürümü
40 şant sürümü, yardımcı temas
50 şant salınımı, yetersiz voltaj salımı
60 İki Set Yardımcı Kontak
70 yardımcı temas, yetersiz voltaj salınımı
18 şant sürümü, alarm teması
28 Yardımcı İletişim, Alarm Kişisi
38 Yetersiz Voltaj Sürümü, Alarm Kontağı
48 Şant tahliyesi, yardımcı temas, alarm teması
58 Şant salınımı, yetersiz voltaj sürümü, alarm teması
68 İki Set Yardımcı Kontak, Alarm Kişisi
78 Yardımcı Kontak, Alt voltaj Sürümü, Alarm Kontağı
10y Ön ödemeli metre özel sürüm
40y Ön ödemeli sayaçlı özel sürüm, yardımcı temas
50y Ön Ödemeli Sayaç Özel Sürüm, Yardımcı Kontak, Yetersiz Voltaj Sürümü
18y Ön ödemeli metre özel sürüm, alarm teması
48y Ön ödemeli metre özel sürüm, yardımcı kontak, alarm kontağı
58y Ön ödemeli sayaçlı özel sürüm, düşük voltaj sürümü, alarm kontağı

H

Başvuru

Dağıtım için kod yok; motor koruma için 2

Ben

Geleneksel ürünler

Kod yok; şeffaf kapak ürünleri için t

J

Amper

10、16、20、25、32、63、80、100、125、160、180、200
、225、250、315、350、400、500、630、700、800、1000
、1250

   

    Örnek: DAM2 (CM1) L-100 /33102 63A DAM2 (CM1) Tipli Kalıplı Kalıplı Kılıf Devre Kesici, Çerçeveli Akım 100A, Kırılma Kapasitesi Motor Koruma için Standart Tip, Tutma İşlemi, 3 Kutup, Çift Serbest Bırakma, SHUNTRELEASE, SHUNTRELEASE için , derecelendirilen akım 63A'dır. Seçim, kurulum, kullanım ürün kılavuzu veya ilgili ulusal standartlarla tutarlı olmalıdır.
    Not: N-Pole tipi 4P devre kesici, B türüne göre varsayılanlar belirtilmeyen A tipi B tipine ayrılır.


Ürün Özellikleri

 Ortam hava sıcaklığı: -5 ℃ ~ +40 ℃ ve 24 saatte ortalama sıcaklık +35 ℃ altındadır.

 Yükseklik: Kurulum sitesinin rakımı 2000 metreden fazla değildir.

 Atmosferik Koşullar: En yüksek sıcaklıktaki hava bağıl nemi +40 ℃%50'den fazla değildir; Düşük sıcaklıkta daha yüksek bağıl neme sahip olabilir. Maksimum ortalama bağıl nem%90'dır, aylık ortalama minimum sıcaklık +25 ℃'dir ve jel yüzeyindeki üründeki sıcaklık değişikliklerini göz önünde bulundurur.

Videolar

Etkili bir çözüme ihtiyaç duyduğunuz yerde, orada bir soruşturmaya ihtiyacınız vardır

Size çözüm üretecek profesyonel bir ekibe mi ihtiyacınız var? Teklif için bizimle iletişime geçin

×

Bize Ulaşın

* Gizliliğinize saygı duyuyoruz. İletişim bilgilerinizi gönderdiğinizde, sizinle yalnızca bizim kurallarımıza uygun olarak iletişim kurmayı kabul ediyoruz.Gizlilik Politikası.

×

Sor

*İsim
*E-posta
*Firma Adı
*Tel
*Mesaj

* Gizliliğinize saygı duyuyoruz. İletişim bilgilerinizi gönderdiğinizde, sizinle yalnızca bizim kurallarımıza uygun olarak iletişim kurmayı kabul ediyoruz.Gizlilik Politikası.