DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)

Przeciążenie termiczne serii DAM1-125 Wyłącznik automatyczny w obudowie formowanej (typ stały)

Wyłączniki serii DAM1 przeznaczone są do przewodzenia prądu w stanie normalnym i wyłączania go przy zwarciach, przeciążeniach, niedopuszczalnych wyboczeniach oraz eksploatacyjnym zadziałaniu i zadziałaniu elementów obwodów elektrycznych. Przeznaczone są do stosowania w jednostkach elektrycznych o napięciu roboczym ograniczonym do 400V na prąd znamionowy od 12,5 do 1600A. Odpowiadają wymaganiom norm EN 60947-1, EN 60947-2

  • Opis produktu
  • Dane techniczne
  • Cechy produktu
  • Więcej szczegółów

Opis produktu

    Wyłączniki serii DAM1 przeznaczone są do przewodzenia prądu w stanie normalnym i wyłączania go przy zwarciach, przeciążeniach, niedopuszczalnych wyboczeniach oraz eksploatacyjnym zadziałaniu i zadziałaniu elementów obwodów elektrycznych. Przeznaczone są do stosowania w jednostkach elektrycznych o napięciu roboczym ograniczonym do 400V na prąd znamionowy od 12,5 do 1600A. Odpowiadają wymaganiom norm EN 60947-1, EN 60947-2 


Wyłączniki termomagnetyczne:

    Funkcja zabezpieczenia termicznego: (do ochrony w warunkach nadmiernego obciążenia) Bimetal, który zapewnia ochronę termiczną, składa się z połączenia dwóch metali o różnych współczynnikach rozszerzalności pod wpływem ciepła. Po podgrzaniu bimetal wygina się w kierunku metalu z mniejszym wydłużeniem. W ten sposób zostaje zwolnione wycięcie ułatwiające otwieranie mechanizmu wyłącznika, co powoduje wyłączenie wyłącznika. Prędkość zginania bimetalu jest wprost proporcjonalna do wielkości prądu przepływającego przez wyłącznik. Ponieważ wzrost prądu oznacza wzrost ciepła. W ten sposób funkcję zabezpieczenia nadprądowego wyłącznika spełnia bimetal przy prądach obciążenia wyższych od prądu znamionowego.


Funkcja ochrony magnetycznej (do ochrony w warunkach zwarcia)

    Kolejną funkcją wyłącznika jest ochrona podłączonego obwodu przed zwarciami. Zwarcie może nastąpić w wyniku zetknięcia się faz ze sobą lub kontaktu faza-ziemia. Ponieważ w przypadku zwarcia przez kable będzie przepływał bardzo duży prąd, energia systemu powinna zostać odcięta w krótszym czasie ze względu na zabezpieczenie termiczne. Wyłącznik powinien wykonać natychmiastowe otwarcie, aby chronić obciążenie, do którego jest podłączony. Częścią spełniającą tę funkcję jest mechaniczny mechanizm otwierający, działający w oparciu o namagnesowanie wywołane polem magnetycznym utworzonym przez prąd zwarciowy.

    Wyłączniki kompaktowe to wyłączniki niskiego napięcia. Spełniają wymagania instalacyjne małych użytkowników, aż po duże podstacje przemysłowe i systemy dystrybucji energii. Są powszechnie stosowane w hutach stali, platformach wiertniczych, szpitalach, systemach kolejowych, lotniskach, centrach obliczeniowych, budynkach biurowych, centrach kongresowych, teatrach, drapaczach chmur i innych konstrukcjach o dużej skali.


Dane techniczne

Parametry elektryczne wyłącznika kompaktowego DAM1 MCCB


Termimagnetyczne wyłączniki MCCB typu stałego

Zdjęcie

Model

kod

  Icu (KA)

Układy scalone (KA)

Prąd znamionowy

Interfejs użytkownika (V)

UE(V)

Polak

Uimp(V)

DAM1-160 1P MCCB moulded case circuit breaker.jpg

DAM1-160

B

25

18.75

10 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63- 80 - 100 - 125-160A

500 V

230 V

1P

10000

N

36

27

DAM1-250 3P moulded case circuit breaker.jpg

DAM1-200

B

25

18.75

10 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63- 80 - 100 - 125-160(200)A

750 V

400 V

2P

10000

N

36

27

DAM1-125 3P

DAM1-125 4P


DAM1-125

B

25

12.5

10 - 12,5 - 16 - 20 - 25 - 32(30) - 40 - 50 - 63(60) - 80 - 100 - 125A

750 V

400 V

3P/4P

10000

N

35

17.5

S

50

37.5

DAM1-160 2P MCCB moulded case circuit breaker

DAM1-160 3P moulded case circuit breaker


DAM1-160

B

25

12.5

10- 12,5-16-20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 -125 - 160(150)A

750 V

400/415 V

3P/4P

8000

N

35

26.25

S

50

37.5

DAM1-250 3P moulded case circuit breaker

DAM1-250

N

35

26.25

63 - 80-100-125 - 160(180) - 200(225) - 250(320)A

750 V

400/415 V

3P/4P

8000

S

50

37.5

H

65

48.75

G

85

51

DAM1-400 4P MCCB moulded case circuit breaker

DAM1-630(400)

N

35

26.25

250 - 315 (350) - 400 - 500 - 630A

750 V

400/415 V

3P/4P

8000

S

50

37.5

H

70

52.5

G

85

52.5

DAM1-800 MCCB moulded case circuit breaker

DAM1-800

N

35

35

400 - 500 - 630 (700) - 800 -1000A

750 V

400/415 V

3P/4P

8000

S

50

37.5

H

70

52.5

G

85

52.5

微信图片_20241112163716

DAM1-1600

S

65

50

800 -1000 - 1250 - 1600A

750 V

400 V

3P/4P

8000

H

85

50

G

100

50


·Icu:Test O-t-CO (O:Manewr Otwarcia, CO:Manewr Zamknięcia-Otwarcia, t:Czas oczekiwania)

·Iks:Test O-t-CO-t-CO (O: manewr otwarcia, CO: manewr Zamknij-Otwarcie, t: Czas oczekiwania)

Pozycja WŁ./I:Wskazuje, że styki wyłącznika są zamknięte. W tej pozycji dźwignia wyłącznika znajduje się w górnym położeniu

Pozycja WYCIECZKI:Wskazuje, że wyłącznik jest otwarty z powodu jakiejkolwiek awarii (przeciążenia lub zwarcia). W tym przypadku dźwignia wyłącznika znajduje się w położeniu środkowym pomiędzy położeniami WŁ. i WYŁ. Aby przełączyć wyłącznik znajdujący się w pozycji wyłączenia do pozycji ON; pchnij dźwignię wyłącznika w dół, jak wskazuje znak WYŁ

Wyłącznik powinien zostać ustawiony z dźwiękiem „kliknięcia”. Następnie pociągnij dźwignię zgodnie ze znakiem ON, aby zamknąć wyłącznik

Pozycja WYŁ./0:Wskazuje, że styki wyłącznika są otwarte. W ten sposób dźwignia wyłącznika znajduje się w dolnym położeniu.

 

Parametry fizyczne wyłącznika kompaktowego DAM1 MCCB

Kategoria (EN 60947-2/IEC 60947-2)

Wytrzymałość



Model

Polak

Właściwości dielektryczne (V)

odległość lonizacji (mm)

Całkowita liczba cykli

Życie elektryczne

Życie mechaniczne

Obwód główny

Obwód pomocniczy

DAM1-160

1P

2500

≤30/0

20000

3000

17000

A/0

AC-15

DAM1-200

2P

2500

≤30/0

15000

2500

12500

A/0

AC-15

DAM1-125

3P/4P

2500

≤30/0

8000

1000

7000

A/0

AC-15

DAM1-160

3P/4P

3000

≤30/0

8000

1000

7000

A/0

AC-15

DAM1-250

3P/4P

3000

≤30/0※

8000

1000

7000

A/B

AC-15

DAM1-630(400)

3P/4P

3000

≤60/0※

5000

1000

4000

A/B

AC-15

DAM1-800

3P/4P

3000

≤80/0※

5000

1000

4000

A/B

AC-15

DAM1-1600

3P/4P

3000

≤80/0※

3000

500

2500

A/B

AC-15

 

>> Rozmiar wyłącznika kompaktowego MCCB

Model

Polak

 

Wymiar konturowy

(LXSXW)

 

DAM1-160

1P

120x30x70mm

DAM1-200

2P

120x60x70mm

DAM1-125

3P

120x76x70mm

4P

120x101x70mm

DAM1-160

3P

120x90x70mm

4P

120x120x70mm

DAM1-250

3P

170 x 105 x 103,5 mm

4P

170 x 140 x 103,5 mm

DAM1-630(400)

3P

254 x 140 x 103,5 mm

4P

254 x 184 x 103,5 mm

DAM1-800

3P

268 x 210 x 103,5 mm

4P

268 x 280 x 103,5 mm

DAM1-1600

3P

410 x 210 x 138,5 mm

4P

410 x 280 x 138,5 mm


Cechy produktu

Łatwa niezależna instalacja urządzeń pomocniczych:

  Styk alarmowy;

  Styk pomocniczy;

  Zwolnienie pod napięciem;

  Wyzwalacz wzrostowy;

  Mechanizm obsługi uchwytu;

  Elektryczny mechanizm napędowy;

  Urządzenie wtykowe;

  urządzenie wysuwne

  Standardowy zestaw każdego wyłącznika składa się z szyn przyłączeniowych lub końcówek kablowych, separatorów faz, kompletu śrub i nakrętek do jego montażu na panelu instalacyjnym.

  Za pomocą specjalnego zacisku 125 i 160 jednostek można zainstalować na din-szyld.

  Waga i wymiary tych wyłączników są o 10-20% mniej niż sugerowane przez innych producentów domów. Fakt ten przewiduje montaż mniejszych pudełek i paneli. Poza tym małe wymiary umożliwiają zmianę starych wyłączników na Dam1.

Filmy

Tam, gdzie potrzebujesz skutecznego rozwiązania, tam potrzebne jest zapytanie

Potrzebujesz profesjonalnego zespołu, który dostarczy Ci rozwiązania? Skontaktuj się z nami, aby uzyskać wycenę

×

Skontaktuj się z nami

*Szanujemy Twoją prywatność. Kiedy przesyłasz swoje dane kontaktowe, zgadzamy się kontaktować się z Tobą wyłącznie zgodnie z naszymiPolityka prywatności.

×

Pytać się

*Nazwa
*E-mail
*Nazwa firmy
*Tel
*Wiadomość

*Szanujemy Twoją prywatność. Kiedy przesyłasz swoje dane kontaktowe, zgadzamy się kontaktować się z Tobą wyłącznie zgodnie z naszymiPolityka prywatności.