DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)
DAM1-125 series thermal overload operation Moulded case circuit breaker(Fixed type)

Работа при тепловой перегрузке серии DAM1-125 Автоматический выключатель в литом корпусе (фиксированного типа)

Выключатели серии ДАМ1 предназначены для проведения тока в нормальном режиме и отключения его при коротких замыканиях, перегрузках, недопустимых перенапряжениях, а также оперативного включения и отключения частей электрической цепи. Предназначены для использования в электроустановках с ограничением рабочего напряжения до 400В на номинальный ток от 12,5 до 1600А. Соответствуют требованиям EN 60947-1, EN 60947-2.

  • Описание продукта
  • Технические характеристики
  • Особенности продукта
  • Подробнее

Описание продукта

    Выключатели серии ДАМ1 предназначены для проведения тока в нормальном режиме и отключения его при коротких замыканиях, перегрузках, недопустимых перенапряжениях, а также оперативного включения и отключения частей электрической цепи. Они предназначены для использования в электроустановках с ограничением рабочего напряжения до 400В на номинальный ток от 12,5 до 1600А. Соответствуют требованиям EN 60947-1, EN 60947-2. 


Термомагнитные выключатели:

    Функция тепловой защиты: (для защиты в условиях перегрузки) Биметалл, обеспечивающий тепловую защиту, состоит из комбинации двух металлов с разными коэффициентами расширения при нагревании. Когда биметалл нагревается, он изгибается в сторону металла с меньшим растяжением. Таким образом, выемка, которая помогает открыть механизм выключателя, освобождается и выключает выключатель. Скорость изгиба биметалла находится в прямой зависимости от величины тока, проходящего через прерыватель. Потому что увеличение тока означает увеличение тепла. Таким образом, функция защиты от перегрузки по току выключателя выполняется биметаллом при токах нагрузки, превышающих номинальный ток.


Функция магнитной защиты (для защиты от короткого замыкания)

    Еще одной функцией автоматического выключателя является защита подключенной цепи от коротких замыканий. Короткое замыкание может произойти в результате контакта фаз между собой или контакта фазы с землей. Поскольку в случае короткого замыкания по кабелям будет проходить очень большой ток, за счет тепловой защиты энергия системы должна быть отключена за более короткое время. Выключатель должен выполнять мгновенное размыкание для защиты нагрузки, к которой он подключен. Частью, выполняющей эту функцию, является механический механизм открывания, который работает за счет намагничивания, вызванного магнитной областью, образованной током короткого замыкания.

    Автоматические выключатели в литом корпусе представляют собой низковольтные выключатели. Они удовлетворяют потребности установки как небольших пользователей, так и крупных промышленных подстанций и систем распределения электроэнергии. Они обычно применяются на сталелитейных заводах, нефтяных платформах, больницах, железнодорожных системах, аэропортах, вычислительных центрах, офисных зданиях, конференц-центрах, театрах, небоскребах и других крупномасштабных сооружениях.


Технические характеристики

Электрические параметры автоматического выключателя в литом корпусе DAM1 MCCB


Термомагнитный автоматический выключатель фиксированного типа

Фото

Модель

код

  Ику (Калифорния)

ИС (КА)

Номинальный входной ток

Уи(В)

Уэ(В)

Полюс

Уимп(В)

DAM1-160 1P MCCB moulded case circuit breaker.jpg

ДАМ1-160

Б

25

18.75

10 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 - 125-160А

500В

230В

10000

Н

36

27

DAM1-250 3P moulded case circuit breaker.jpg

ДАМ1-200

Б

25

18.75

10 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 - 125-160(200)А

750В

400В

10000

Н

36

27

DAM1-125 3P

DAM1-125 4P


ДАМ1-125

Б

25

12.5

10 - 12,5 - 16 - 20 - 25 - 32(30) - 40 - 50 - 63(60) - 80 - 100 - 125А

750В

400В

3П/4П

10000

Н

35

17.5

С

50

37.5

DAM1-160 2P MCCB moulded case circuit breaker

DAM1-160 3P moulded case circuit breaker


ДАМ1-160

Б

25

12.5

10- 12,5-16-20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 -125 - 160(150)А

750В

400/415В

3П/4П

8000

Н

35

26.25

С

50

37.5

DAM1-250 3P moulded case circuit breaker

ДАМ1-250

Н

35

26.25

63 - 80-100-125 - 160(180) - 200(225) - 250(320)А

750В

400/415В

3П/4П

8000

С

50

37.5

ЧАС

65

48.75

Г

85

51

DAM1-400 4P MCCB moulded case circuit breaker

ДАМ1-630(400)

Н

35

26.25

250–315 (350)– 400–500 – 630А

750В

400/415В

3П/4П

8000

С

50

37.5

ЧАС

70

52.5

Г

85

52.5

DAM1-800 MCCB moulded case circuit breaker

ДАМ1-800

Н

35

35

400-500-630(700)-800-1000А

750В

400/415В

3П/4П

8000

С

50

37.5

ЧАС

70

52.5

Г

85

52.5

微信图片_20241112163716

ДАМ1-1600

С

65

50

800-1000-1250-1600А

750В

400В

3П/4П

8000

ЧАС

85

50

Г

100

50


·Ику:Тест O-t-CO(O:Маневр открытия,CO:Маневр закрытия-открытия,t:Продолжительность ожидания)

·Икс: Тест O-t-CO-t-CO (O: маневр открытия, CO: маневр закрытия-открытия, t: продолжительность ожидания)

Положение ВКЛ/I:Указывает на то, что контакты выключателя замкнуты. В этом положении рычаг прерывателя находится в верхнем положении.

Положение ПУТЕШЕСТВИЯ: Это указывает на то, что выключатель разомкнут из-за какой-либо неисправности (перегрузки или короткого замыкания). В этом случае рычаг прерывателя находится в среднем положении между положениями ВКЛ и ВЫКЛ. Чтобы перевести выключатель, находящийся в положении отключения, в положение ВКЛ.; нажмите рычаг прерывателя вниз, как показано знаком ВЫКЛ.

Выключатель должен быть установлен со звуком щелчка. После этого потяните рычаг, как показано знаком ВКЛ, чтобы замкнуть выключатель.

ВЫКЛ/0 положение:Указывает на то, что контакты выключателя разомкнуты. Таким образом, рычаг прерывателя находится в нижнем положении.

 

Физические параметры автоматического выключателя в литом корпусе DAM1 MCCB

Категория (EN 60947-2/IEC 60947-2)

Выносливость



Модель

Полюс

Диэлектрические свойства (В)

Расстояние ионизации (мм)

Всего циклов

Электрическая жизнь

Механическая жизнь

Главная цепь

Вспомогательная цепь

ДАМ1-160

2500

≤30/0

20000

3000

17000

А/0

АС-15

ДАМ1-200

2500

≤30/0

15000

2500

12500

А/0

АС-15

ДАМ1-125

3П/4П

2500

≤30/0

8000

1000

7000

А/0

АС-15

ДАМ1-160

3П/4П

3000

≤30/0

8000

1000

7000

А/0

АС-15

ДАМ1-250

3П/4П

3000

≤30/0※

8000

1000

7000

А/Б

АС-15

ДАМ1-630(400)

3П/4П

3000

≤60/0※

5000

1000

4000

А/Б

АС-15

ДАМ1-800

3П/4П

3000

≤80/0※

5000

1000

4000

А/Б

АС-15

ДАМ1-1600

3П/4П

3000

≤80/0※

3000

500

2500

А/Б

АС-15

 

>> Размер автоматического выключателя в литом корпусе MCCB

Модель

Полюс

 

Контурный размер

(ДXШXВ)

 

ДАМ1-160

120х30х70мм

ДАМ1-200

120х60х70мм

ДАМ1-125

120х76х70мм

120х101х70мм

ДАМ1-160

120х90х70мм

120х120х70мм

ДАМ1-250

170x105x103,5 мм

170x140x103,5 мм

ДАМ1-630(400)

254x140x103,5 мм

254x184x103,5 мм

ДАМ1-800

268x210x103,5 мм

268x280x103,5 мм

ДАМ1-1600

410x210x138,5 мм

410x280x138,5 мм


Особенности продукта

Легкая самостоятельная установка вспомогательных устройств:

  Контакт сигнализации;

  Вспомогательный контакт;

  Расцепитель пониженного напряжения;

  Шунт релиз;

  Обрабатывать механизм работы;

  Электрический приводной механизм;

  Подключаемое устройство;

  Вытягивание устройства;.

  Стандартный набор каждого выключателя схемы состоит из соединения шиновых выборок или кабельных выдуль, фазовых сепараторов, набора винтов и гайков для его установки на панели установки.

  С помощью специального зажима блоки 125 и 160 можно установить на DIN-рейку.

  Вес и габариты этих автоматических выключателей на 10-20% меньше предлагаемых другими отечественными производителями. Этот факт предусматривает монтаж коробов и панелей меньшего размера. Кроме того, небольшие габариты позволяют заменить старые выключатели на ДАМ1.

Видео

Там, где вам нужно эффективное решение, вам нужен запрос

Вам нужна профессиональная команда, которая предоставит вам решения? Свяжитесь с нами для получения предложения

×

Связаться с нами

*Мы уважаем вашу конфиденциальность. Когда вы отправляете свою контактную информацию, мы соглашаемся связываться с вами только в соответствии с нашимиПолитика конфиденциальности.

×

Запросить

*Имя
*Электронная почта
*Название компании
*Тел.
*Сообщение

*Мы уважаем вашу конфиденциальность. Когда вы отправляете свою контактную информацию, мы соглашаемся связываться с вами только в соответствии с нашимиПолитика конфиденциальности.