Quick closing: ensuring reliable operation of impact loads and extending the life of circuit breakers;

There is a clear opening and dlosing indicator window below the handle;

The printed informnation on the surface of the product is long-lasting, clear, and not easy to erase;

The emission of ionized gases is subject to the strictest restrictions: 45mm grid distance;

This product complies with Type B of IEC 60898-1 standard, The characteristics of the C-type and D-type

trip curves.


  • Product Description
  • Specifications
  • Product Features
  • More Details

Product Description

●Technical Specifications

 

●Polarity: 1P, 2P, 3P, 4P;

●Compliant with standards: IEC60898- 1/GB/T10963.1;

●Product Function: Overload and Short Circuit Protection;

●Certification: CE,CB,SAA; .

●Rated current In (A):2,4, 6, 10, 16, 20, 25, 32, 40, 50, 63;

●Rated voltage Ue: 230/240V (1P),400/415V(2P ~ 4P);

●Rated frequency (Hz): 50/60;

●Rated insulation voltage: 500V;

●Rated impulse withstand voltage (Uimpact) kU: 4;

●Rated breaking capacity Icn (kA): 6/10kA;

●Protection level: IP20;

●Electrical lifespan (times): 10,000;

●Mechanical lifespan (times): 30,000;

●Breaking ability:

●Flame retardancy: V0 level;

●Installation location: Any location;

●Applicable wire cross-section; Solid wire (mm): 1-35; Twisted wire (mm2): 1-25;

●Maximum wiring torque (N . m): 3.5;

●Environmental temperature (C ): -25 to+45, maximum humidity of 95%;

●Storage temperature (C):- 40~ +75;

●Energy limit level: 3;

●Installation altitude (meters): not exceeding 2000.


Specifications

●Technical Specifications

 

●Polarity: 1P, 2P, 3P, 4P;

●Compliant with standards: IEC60898- 1/GB/T10963.1;

●Product Function: Overload and Short Circuit Protection;

●Certification: CE,CB,SAA; .

●Rated current In (A):2,4, 6, 10, 16, 20, 25, 32, 40, 50, 63;

●Rated voltage Ue: 230/240V (1P),400/415V(2P ~ 4P);

●Rated frequency (Hz): 50/60;

●Rated insulation voltage: 500V;

●Rated impulse withstand voltage (Uimpact) kU: 4;

●Rated breaking capacity Icn (kA): 6/10kA;

●Protection level: IP20;

●Electrical lifespan (times): 10,000;

●Mechanical lifespan (times): 30,000;

●Breaking ability:

●Flame retardancy: V0 level;

●Installation location: Any location;

●Applicable wire cross-section; Solid wire (mm): 1-35; Twisted wire (mm2): 1-25;

●Maximum wiring torque (N . m): 3.5;

●Environmental temperature (C ): -25 to+45, maximum humidity of 95%;

●Storage temperature (C):- 40~ +75;

●Energy limit level: 3;

●Installation altitude (meters): not exceeding 2000.

●Tripping Characteristic Curves

IEC 60898-1

1

Magnetic Release

When a circuit short circuit occurs, instantaneous tripping is achieved by a magnet with an iron core. According to the 1EC60898 standard, this product can be divided into three types: B, C, and D.


Test current

Tripping time

Applications

B Curve

3ln
5ln

0.1<t<45s(In ≦ 32A)
0.1<T<90s(In>32A)

Type B is only applicable to active loads:
-Electric heater-Water heater-Electric furmace

C Curve

5In
10ln

0.1<t<15s(In ≦ 32A)
0.1<T<30s(In>32A)t<0.1s

Type C is suitable for ordinary loads:
-Lamp
-Power socket
-Small power motor

D Curve

10ln
20In

0.1<t<4s(In ≦ 32A)
0.1<T<8s(ln>32A)
t<0.1s

Control and protect circuits with instantaneous surge current
(large motors)

● Thermal Release

●Once overload occurs in the circuit, the bimetallic strip of the circuit breaker will bend due to heat, causing the contacts to disconnect and resulting in

thermal tripping;

●The IEC standard defines the tripping time range for different overload currents;

●The reference test environment temperature is 30 °C.

Test current

Tripping time

1.13ln

t z 1h(in ≦ 63A)

1.45ln

t<1h(In ≦ 63A)

2.55ln

1s<1h<60s(In≤32A)1s<t<120s(In>32A)

●Product and installation dimensions(MM)

The product is mounted on a guide rail with a maximum connection capacity of 25mm2.

2

Product Features

●Features

  Quick closing: ensuring reliable operation of impact loads and extending the life of circuit breakers;

  There is a clear opening and dlosing indicator window below the handle;

  The printed informnation on the surface of the product is long-lasting, clear, and not easy to erase;

  The emission of ionized gases is subject to the strictest restrictions: 45mm grid distance;

  This product complies with Type B of IEC 60898-1 standard, The characteristics of the C-type and D-type trip curves.

Videos

Where you need an efficient solution, there you need an inquiry

Do you need a professional team to provide you with solutions? Contact us for a quote

×

Contact Us

*We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.

×

Inquire

*Name
*Email
*Company Name
*Tel
*Message

*We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.