Residual current operated circuit breakers with overcurrent protection DABF-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. 
They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.


  • Product Description
  • Specifications
  • Product Features
  • More Details

Product Description

Residual current operated circuit breakers with overcurrent protection DABF-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. 
They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.

  Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series.

  The most subtle electric shock hazard protection in case of direct contact with conducting parts.

  Independent contact position indicator.

  Wide range of operating temperatures from –25 to +40° С.

  Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.

  “TEST” button for checking the device’s operation and accuracy of connection.

  DABL dimensions correspond to 2-modular item at the expense of constructive elements placement.

  Boosted capability of 6 kA provides for installing AVDTs as incoming protection switches.


Specifications

RCBO DABF-63 Magnetic type
For protection of general power distribution (IEC/EN 60898-1)dabl-63 1p+n rcbo circuit breaker nova (1)
Poles of number1P+N,3P+N
Electrical performance
Rated current   In( A )6-63A
Release typeMagnetic type
FunctionsProtection against short circuit , leakage ,overload, over voltage,isolation
Type of residual currentAC and A
Rated frequency   f ( Hz)50-60Hz
Rated working voltage Ue (V) AC230/400
Rated residual current motion   I△n( mA)10,30,100,300
Rated residual current no-motion  I△no( mA)5,15,25,50,300
cosф 0.5
Insulation voltage  Ui500V
Rated impulse withstand voltage   Uimp6KV
Instantaneous tripping type  B/C/D
Rated short circuit Icn(kA)            6/10
Service life(O~C)Mechanical 12000
Electrical 6000
Connection and installation
Protection degreeIP40
Wire                                             mm²1~25
Working temperature (with daily average≤35℃)-5 ~+40℃
Resistance to humidity and heatClass 2
Altitude above sea≤2000
Relative humidity+20℃ , ≤90% ;+40℃ , ≤50%
Pollution degree2
Installation environmentAvoid obvious shock and vibration
Installation classClass Ⅱ , Class Ⅲ
Combination with accessories
Auxiliary contactYes
Alarm contactYes
ALT+AUXYes
Shunt releaseYes
Undervoltage release-
Overvoltage releaseYes
图片1Dimensions(mm)                                            (WxHxL)                                                                                 a35
b80.4
c72








Product Features


图片1.jpg

Combined circuit with an electronic module of differential protection, D-class varistor and integrated circuit breaker of DAB7-63 series ensures 4 types of protection: from residual current (leakage current), short circuit; overload and surge overvoltage.

图片2.jpg

Welding deposition of silver-bearing composite provides for boosting the contact block’s wear-resistance and lowering the transient one.

 图片3.jpg

Main circuit status indicator provides exact information on the contacts status independently from lever position.

 图片4.jpg

Wide range of operating temperatures from –25 to +40° С contributes to applying this switch in different climatic zones.

 图片5.jpg

“TEST” button for checking the device’s operation and accuracy of connection.

 图片6.jpg

Notches on terminal clamps allow lowering thermal losses and boosting the mechanical stability of connection.

  图片7.jpg

Boosted screw head dimension with cross-functional crest (+,–) helps to facilitate mounting and prevents the screws from falling out during the installation.

 


Videos

Where you need an efficient solution, there you need an inquiry

Do you need a professional team to provide you with solutions? Contact us for a quote

×