DAM1L-160 Earth Leakage protection circuit breaker (ELCB)
DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology.
- Product Description
- Specifications
- Product Features
- More Details
Product Description
DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology.Protected moulded case type circuit breaker.
The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated In a power distribution network with a current of 10A~500A and a rated working voltage of 380V/400V, it is used to distribute electric energy and protect the overload and short circuit of lines and power equipment.Under normal conditions,It can also be used for infrequent switching of lines.
This circuit breaker also has the following protection:
It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection.
Provide protection against the danger of increasing ground voltage due to insulation damage;
Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection.
Circuit breakers with rated current of 500A and below can also be used for infrequent start, break off during operation and overload and short circuit protection of squirrel cage motors.
DAM1L series circuit breakers can be equipped with electric accessories and mechanical accessories for various purposes, such as separately excited tripping device, auxiliary contact, alarm contact and rotating handle operating mechanism.
This series of circuit breakers are widely used in construction, transportation, tunnel, residence, etc.The delay type in this series of circuit breakers is used for branch lines Distribution of roads;Adjustable type is used to adjust the residual action current or disconnection time on site.
Specifications
Residual current circuit breaker basic parameters | |||
COSφ |
Rated current of remnant motion I△n (mA)
|
Rated current of remnant no-motion I△no (mA)
| Max-Breaking time (S) |
0.2 | 100,300,500 | 50,150,250 | 0.05,0.5, 0.8 |
Rated residual operating current(mA) | Rated no tripping current value.I△no(mA) | Residual current value range.(mA)0.5x(I△n+I△no)±0.2I△n |
30 | 15mA | 18mA-27mA |
100 | 50mA | 60mA-90mA |
300 | 150mA | 180mA-270mA |
500 | 250mA | 300mA-450mA |
1000 | 500mA | 600mA-900mA |
Earth-Leakage Circuit Breakers(ELCB) |
|
| ||||||
Model | DAM1-125L | DAM1-160L | ||||||
Breaking Capacity Code | B | N | S | B | N | S | ||
Rated Current of Frame size- Inm (A) | 125A | 160A | ||||||
Rated Current-In(40,50 or 55℃) (A) | 10 - 12,5 - 16 - 20 - 25 - 32(30) - 40 - 50 - 63(60) - 80 - 100 - 125A | 10- 12,5-16-20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 -125 - 160(150)A | ||||||
Ui (V) | 690V | 690V | ||||||
Ue (V) | 400V | 400/415V | ||||||
Number of Pole | 4P | 4P | ||||||
Icu (KA) | 25 | 35 | 50 | 25 | 35 | 50 | ||
Ics(KA) | 12.5 | 17.5 | 37.5 | 12.5 | 26.25 | 37.5 | ||
Icm(peak)/cos ф (KA) | 40/0.3 | 73.5/0.25 | 105/0.25 | 41/0.3 | 73.5/0.25 | 110/0.25 | ||
(I△m)KA/cosф | 9/0.5 | 19/0.5 | ||||||
Residual current threshold(mA) | 100-300-500 | 100-300-500 | ||||||
Time delay(ms) | 50-500-800 | 50-500-800 | ||||||
Uimp (V) | 10000 | 8000 | ||||||
Dielectric Propery (V) | 2500 | 3000 | ||||||
lonization distance (mm) | ≤30/0 | ≤30/0 | ||||||
Endurance | Total Cycles | 8000 | 8000 | |||||
Electrical Life | 1000 | 1000 | ||||||
Mechanical Life | 7000 | 7000 | ||||||
Category (EN 60947-2/IEC 60947-2) | Main circuit | A/0 | A/0 | |||||
Auxiliary circuit | AC-15 | AC-15 | ||||||
Under Voltage Release | √ | √ | ||||||
Shunt Release | √ | √ | ||||||
Auxiliary Contact | √ | √ | ||||||
Alarm Contact | √ | √ | ||||||
Auxiliary Contact and Alarm Contact | √ | √ | ||||||
Handle Operation Mechanism | √ | √ | ||||||
Electrical Operastion Mechanism | √ | √ | ||||||
Terminal cover | √ | √ | ||||||
Phase seperator | √ | √ | ||||||
| W (mm) | 3P | - | - | ||||
4P | 101 | 120 | ||||||
L (mm) | 3P | - | - | |||||
4P | 155 | 120 | ||||||
H (mm) | 3P | - | - | |||||
4P | 70 | 70 | ||||||
Weight | Fixed version 3P/4P | - | - | |||||
Plug-in version 3P/4P | - | - | ||||||
Draw out version 3P/4P | - | - |
Earth-Leakage Circuit Breakers(ELCB) |
|
| ||||||||
Model | DAM1-250L | DAM1-400L | ||||||||
Breaking Capacity Code | N | S | H | G | N | S | H | G | ||
Rated Current of Frame size- Inm (A) | 250A | 400A | ||||||||
Rated Current-In(40,50 or 55℃) (A) | 63 - 80-100-125 - 160(180) - 200(225) - 250(320)A | 250 - 315 (350)- 400 - 500A | ||||||||
Ui (V) | 690V | 690V | ||||||||
Ue (V) | 400/415V | 400/415V | ||||||||
Number of Pole | 4P | 4P | ||||||||
Icu (KA) | 35 | 50 | 65 | 85 | 35 | 50 | 70 | 85 | ||
Ics(KA) | 26.25 | 37.5 | 48.75 | 51 | 26.25 | 37.5 | 52.5 | 52.5 | ||
Icm(peak)/cos ф (KA) | 77/0.25 | 114/0.25 | 143/0.2 | 178/0.2 | 70/0.25 | 110/0.25 | 154/0.2 | 187/0.2 | ||
(I△m)KA/cosф | 12/0.3 | 19/0.5 | ||||||||
Residual current threshold(mA) | 100-300-500 | 100-300-500 | ||||||||
Time delay(ms) | 50-500-800 | 50-500-800 | ||||||||
Uimp (V) | 8000 | 8000 | ||||||||
Dielectric Propery (V) | 3000 | 3000 | ||||||||
lonization distance (mm) | ≤30/0※ | ≤60/0※ | ||||||||
Endurance | Total Cycles | 8000 | 5000 | |||||||
Electrical Life | 1000 | 1000 | ||||||||
Mechanical Life | 7000 | 4000 | ||||||||
Category (EN 60947-2/IEC 60947-2) | Main circuit | A/B | A/B | |||||||
Auxiliary circuit | AC-15 | AC-15 | ||||||||
Under Voltage Release | √ | √ | ||||||||
Shunt Release | √ | √ | ||||||||
Auxiliary Contact | √ | √ | ||||||||
Alarm Contact | √ | √ | ||||||||
Auxiliary Contact and Alarm Contact | √ | √ | ||||||||
Handle Operation Mechanism | √ | √ | ||||||||
Electrical Operation Mechanism | √ | √ | ||||||||
Terminal cover | √ | √ | ||||||||
Phase seperator | √ | √ | ||||||||
| W (mm) | 3P | - | - | ||||||
4P | 140 | 184 | ||||||||
L (mm) | 3P | - | - | |||||||
4P | 210 | 254 | ||||||||
H (mm) | 3P | - | - | |||||||
4P | 103.5 | 103.5 | ||||||||
Weight | Fixed version 3P/4P | - | 41.5/5.5 | 5.1/7.1 | ||||||
Plug-in version 3P/4P | - | 4.6/6 | 6.5/8.5 | |||||||
Draw out version 3P/4P | - | 5/6.4 | 6.5/8.7 |
·Icu:O-t-CO test(O:Open maneuver,CO:Close-Open maneuver,t:Waiting duration)
·Ics:O-t-CO-t-CO test(O:open maneuver,CO:Close-Open maneuver,t:Waiting duration)
Product Features
Range:10A to 500A(AC)
integral structure, small volume, high breaking capacity, safe and reliable.
Adjustable magnetic setting(0.8-1times)In.
Push to trip button provision.
Separate main and arcing contacts
Can be adjusted the residual action current or disconnection time according to the actual use.
Strong anti-interference ability.
Wide range of accessories.
The working power of the residual current protection circuit of this series of circuit breakers is supplied by the multi-phase power supply (the working power of the protection circuit of early products is supplied by the single-phase power supply)the residual current protection circuit of the device can still operate normally.When the operating power voltage of the circuit breaker's residual current protection circuit is reduced to 50V, the circuit breaker's residual current protection circuit can still work normally.(I coherence n=30mA)
This series of circuit breakers are classified into B type (i.e., basic breaking capacity) (Inm less than 100), S type (i.e., standard breaking capacity) and H type (i.e High score breaking capacity (Inm > 160) can be used in different situations.
The main circuit of a circuit breaker is connected in many ways:
Piston front connection
Terminal extension plate front connection
The screw connection at the rear of the piston plate
![](https://dada.usa18.wondercdn.com/uploadfile/202411/8cfce987c6e4231.jpg)
Videos
Related Solutions
-
Mining Industry
The mining industry involves the extraction of valuable minerals or other geological materials from the Earth. The industry plays a crucial role in providing raw materials for various sectors, including construction, manufacturing, and energy production. However, the mining industry faces several challenges
-
Rail Transportation
Rail transportation plays a vital role in the logistics and mobility infrastructure of countries worldwide. It offers an efficient and environmentally friendly way to transport goods and passengers over long distances.
-
Server Room
Server rooms are critical facilities that house computer servers, networking equipment, and data storage systems. They play a pivotal role in ensuring the smooth operation of IT infrastructure for businesses.
-
Drilling Platform
Drilling platforms are essential structures in the oil and gas industry, enabling the extraction of hydrocarbons from beneath the Earth's surface. These platforms can be fixed or floating and are designed to withstand harsh marine environments.
-
Mining Equipment
The development of mining equipment has been driven by the need to extract resources from increasingly difficult-to-reach locations and to process larger quantities of ore with greater efficiency.
-
Industrial Manufacturing
Today, the industry faces new challenges and opportunities, driven by technological advancements, globalization, and changing consumer demands.
-
Power Industry
With the growth of population and industrialization, the demand for electricity has been constantly increasing. This has led to the expansion and modernization of the power industry across the globe.
-
Building Automation
Building automation started with simple mechanical controls and has evolved into sophisticated digital systems that integrate various technologies to enhance building performance and occupant comfort.
Related Videos
-
DC solution
-
Motor protection solution
-
Electrical protection solution
-
Understand the importance of molded case circuit breakers: focus on DAM1 series
The importance of reliable, efficient molded case circuit breakers (MCCB) in electrical installations cannot be overstated. The DAM1 series circuit breakers stand out as the first choice for professio
-
Shanghai Dada Electrical's new product is now launched!
Welcome to the world of DC Circuit Breakers! These innovative devices are designed to protect distribution and group systems with various loads. From drives with moderate starting currents like compre
-
New motor protection circuit breaker by Shanghai Dada Electrical Co., Ltd.
Introducing the new motor protection circuit breaker by Shanghai Dada Electrical Co., Ltd. This essential device provides protection for motors against overloads and short circuits, ensuring the safet